MAIN
Product or component type
Limit switch
Product specific application
Compact box
ETIM classification
ETIM 9 - EC000030 - End switch
Movement of operating head
Linear
Type of operator
Steel spring return roller plunger (-)
Switch actuation
By 30° cam
Type of approach
Lateral approach, 2 directions
Indivisible sale quantity
1
Sale per indivisible quantity
1
COMPLEMENTARY
Mechanical durability
10000000 cycles
Cable entry
1 entry for 1/2" - 14 NPT conforming to ANSI B1.20.1
Repeat accuracy
+/- 0.001 in linear travel of cam
Electrical durability
1000000 cycles
Electrical connection
Screw-clamp terminals (AWG 22...AWG 12), 1-2
Contacts type and composition
NC-NO
Contacts material
Silver contacts
Terminals description ISO n°1
(1-2)NC(3-4)NO
Contact operation
Snap action
[Uimp] rated impulse withstand voltage
2.5 kV AC 1 min conforming to CE, 2.2 kV AC 1 min conforming to UL, 2.64 kV AC 1 s conforming to CSA
[Ui] rated insulation voltage
600 V (pollution degree 3) conforming to UL 508 for contact block, 600 V (pollution degree 3) conforming to CSA C22.2 No 14 for contact block
[Ie] rated operational current
1.2 A at 600 V AC, A600 conforming to NEMA, 1.5 A at 480 V AC, A600 conforming to NEMA, 3 A at 240 V AC, A600 conforming to NEMA, 6 A at 120 V AC, A600 conforming to NEMA, 0.1 A at 600 V DC, Q600 conforming to NEMA, 0.27 A at 250 V AC, Q600 conforming to NEMA, 0.55 A at 125 V DC, Q600 conforming to NEMA
[Ithe] conventional enclosed thermal current
10 A
Electrical shock protection class
Class 0 conforming to IEC 61140
Short-circuit protection
10 A by CC fuse, protection type: non-time delay
Function available
Not applicable
Product weight
1.25 livre
ENVIRONMENT
Environmental characteristic
Standard environment
IP degree of protection
IP67 conforming to IEC 60529
NEMA degree of protection
NEMA 1 conforming to Nema type 250, NEMA 2 conforming to Nema type 250, NEMA 4 conforming to Nema type 250, NEMA 6 conforming to Nema type 250, NEMA 6P conforming to Nema type 250, NEMA 12 conforming to Nema type 250, NEMA 13 conforming to Nema type 250
Ambient air temperature for operation
-29…85 °C
Ambient air temperature for storage
-29…85 °C
Shock resistance
60 gn for 9 ms conforming to IEC 60068-2-27
Vibration resistance
25 gn (f= 10-150 Hz) conforming to IEC 60068-2-6
Protective treatment
Epoxy powder coat
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARRANTY
PACKING UNITS
Country of origin
MX (Mexico)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916098356
Package 1 weight
0.169 kg
New Package 2 GTIN 14
13666916098353
New Package 3 GTIN 14
23666916098350