Inductive sensor, XS1, M18, brass, Sn 5 mm, PNP, NO/NC, M12, L48 mm, flush, TELEMECANIQUE

★★★★★
★★★★★

Inductive sensor, XS1, M18, brass, Sn 5 mm, PNP, NO/NC, M12, L48 mm, flush, TELEMECANIQUE

★★★★★
★★★★★

Comanda instant Inductive sensor, XS1, M18, brass, Sn 5 mm, PNP, NO/NC, M12, L48 mm, flush, TELEMECANIQUE

Inductive sensor, XS1, M18, brass, Sn 5 mm, PNP, NO/NC, M12, L48 mm, flush, TELEMECANIQUE
MAIN
Range of product
Telemecanique Inductive proximity sensors XS
Series name
General purpose
Sensor type
Inductive proximity sensor
Sensor name
XS1
Device application
Mobile equipment
Sensor design
Cylindrical M18
Size
51 mm
Body type
Fixed
Type of output signal
Discrete
Wiring technique
4-wire
Discrete output function
1 NO + 1 NC
Detector flush mounting acceptance
Flush mountable
Discrete output type
PNP
Material
Metal
Electrical connection
Male connector M12, 4 pins
[Us] rated supply voltage
9 V DC with reverse polarity protection
Output circuit type
DC
IP degree of protection
IP69K conforming to DIN 40050, IP65 conforming to IEC 60529, IP67
Detection face
Frontal
Thread type
M18 x 1
Safety level
SIL 2 conforming to IEC 61508, PL = d conforming to ISO 13849-1, SILCL 2 conforming to IEC 62061
Front material
PPS
Safety reliability data
MTTFd = 1810 years, PFHd = 62.9E-9 1/h, SFF = 92 %, DC = 74 % with appropriate safety controller
Sensing range
> 4...8 mm
Differential travel
1...15 % of Sr
Status LED
Output state: 1 LED (yellow)
Current consumption
0...10 mA no-load
Delay first up
5 MILLISECOND
Delay response
0.15 MILLISECOND
Marking
CE
Delay recovery
0.35 MILLISECOND
Product certifications
CSAE2TÜVUL
Vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Standards
IEC 62061ISO 13849-1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
2.5 CENTIMETER
Package 1 width
4 CENTIMETER
Package 1 length
11 CENTIMETER
Package 1 weight
0.058 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
44
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
2.798 KILOGRAM
Unit type of package 3
P06
Number of units in package 3
704
Package 3 height
75 CENTIMETER
Package 3 width
80 CENTIMETER
Package 3 length
60 CENTIMETER
Package 3 weight
52.768 KILOGRAM
Indivisible sale quantity
1
COMPLEMENTARY
Detection face
Frontal
Thread type
M18 x 1
Safety level
SIL 2 conforming to IEC 61508, PL = d conforming to ISO 13849-1, SILCL 2 conforming to IEC 62061
Front material
PPS
Safety reliability data
MTTFd = 1810 years, PFHd = 62.9E-9 1/h, SFF = 92 %, DC = 74 % with appropriate safety controller
Sensing range
> 4...8 mm
Differential travel
1...15 % of Sr
Status LED
Output state: 1 LED (yellow)
Current consumption
0...10 mA no-load
Delay first up
5 MILLISECOND
Delay response
0.15 MILLISECOND
Marking
CE
Delay recovery
0.35 MILLISECOND
Product certifications
CSAE2TÜVUL
Vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Standards
IEC 62061ISO 13849-1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
2.5 CENTIMETER
Package 1 width
4 CENTIMETER
Package 1 length
11 CENTIMETER
Package 1 weight
0.058 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
44
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
2.798 KILOGRAM
Unit type of package 3
P06
Number of units in package 3
704
Package 3 height
75 CENTIMETER
Package 3 width
80 CENTIMETER
Package 3 length
60 CENTIMETER
Package 3 weight
52.768 KILOGRAM
Indivisible sale quantity
1
ENVIRONMENT
Product certifications
CSAE2TÜVUL
Vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Standards
IEC 62061ISO 13849-1
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PACKING UNITS
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
2.5 CENTIMETER
Package 1 width
4 CENTIMETER
Package 1 length
11 CENTIMETER
Package 1 weight
0.058 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
44
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
2.798 KILOGRAM
Unit type of package 3
P06
Number of units in package 3
704
Package 3 height
75 CENTIMETER
Package 3 width
80 CENTIMETER
Package 3 length
60 CENTIMETER
Package 3 weight
52.768 KILOGRAM
Indivisible sale quantity
1
Fii primul care evalueaza acest produs
Pentru a evalua acest produs este necesar sa fii autentificat. > Click aici
Website detinut de Ringhiopol International S.R.L., CIF: RO33473129, Reg.Com: J8/1142/2014