Range of product
Telemecanique Photoelectric sensors XU
Sensor name
XU2
Series name
Application material handling
Product specific application
Not applicable
Enclosure material
Nickel plated brass
Electronic sensor type
Photo-electric sensor
Sensor design
Cylindrical M18
Material
Metal
Electrical connection
1 male connector M12, 4 pins
Wiring technique
3-wire
Detection system
Thru beam
Emission
Infrared thru beam
Kit composition
Transmitter + receiver
Discrete output function
1 NO
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
Type of output signal
Analoguediscrete
Line of sight type
Axial
Supply circuit type
DC
Discrete output type
PNP
Analogue output range
4...20 mA
Delay response
15 MILLISECOND
Product certifications
CECSAUL
Setting-up
Sensitivity adjustment
Output type
Solid state
Lens material
PMMA
Add on output
With analogue output
Add on input
Breaking test (transmitter)
Status LED
1 LED (green) for supply on, 1 LED (yellow) for operation
Sensing range
> 30 m
Delay first up
50 MILLISECOND
Delay recovery
15 MILLISECOND
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protection
IP67 conforming to IEC 60529
Vibration resistance
25 gn, amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
9.4 CENTIMETER
Package 1 length
13 CENTIMETER
Package 1 weight
0.16 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
22
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
3.843 KILOGRAM
Unit type of package 3
CAR
Number of units in package 3
1
Package 3 height
13 CENTIMETER
Package 3 width
4.1 CENTIMETER
Package 3 length
9.4 CENTIMETER
Package 3 weight
0.16 KILOGRAM
Indivisible sale quantity
1
COMPLEMENTARY
Product certifications
CECSAUL
Setting-up
Sensitivity adjustment
Output type
Solid state
Lens material
PMMA
Add on output
With analogue output
Add on input
Breaking test (transmitter)
Status LED
1 LED (green) for supply on, 1 LED (yellow) for operation
Sensing range
> 30 m
Delay first up
50 MILLISECOND
Delay recovery
15 MILLISECOND
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protection
IP67 conforming to IEC 60529
Vibration resistance
25 gn, amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
9.4 CENTIMETER
Package 1 length
13 CENTIMETER
Package 1 weight
0.16 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
22
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
3.843 KILOGRAM
Unit type of package 3
CAR
Number of units in package 3
1
Package 3 height
13 CENTIMETER
Package 3 width
4.1 CENTIMETER
Package 3 length
9.4 CENTIMETER
Package 3 weight
0.16 KILOGRAM
Indivisible sale quantity
1
ENVIRONMENT
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protection
IP67 conforming to IEC 60529
Vibration resistance
25 gn, amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PACKING UNITS
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
9.4 CENTIMETER
Package 1 length
13 CENTIMETER
Package 1 weight
0.16 KILOGRAM
Unit type of package 2
S02
Number of units in package 2
22
Package 2 height
15 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
3.843 KILOGRAM
Unit type of package 3
CAR
Number of units in package 3
1
Package 3 height
13 CENTIMETER
Package 3 width
4.1 CENTIMETER
Package 3 length
9.4 CENTIMETER
Package 3 weight
0.16 KILOGRAM
Indivisible sale quantity
1