MAIN
Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLP
Electrical circuit type
Control circuit
Controlled fluid
Fresh water (0-125 °C), air (-15-125 °C), gas (-15-125 °C), hydraulic oil (-15-125 °C)
Fluid connection type
SAE 7/16-20UNF (female)
Electrical connection
1 male connector EN 175301-803-A (ex DIN43650) 3 pins
[Us] rated supply voltage
24 V DC SELV (voltage limits: 12-33 V)
Type of output signal
Analogue
Analogue output function
0...10 V, 3-wire
Quantity per set
Set of 1
Type of packing
Individual
Materials in contact with fluid
Ceramicfluorocarbon FPMstainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuitreverse polarity
Electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz
Measurement accuracy
+/- 0,5 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K
Repeat accuracy
+/- 0,25 % de la plage de mesure
Standards
IEC 61326-2-3NSF ANSI 61
Product certifications
CEcULusRCM
Vibration resistance
20 gn (f = 10-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
4.5 CENTIMETER
Package 1 length
8.5 CENTIMETER
Package 1 weight
0.096 KILOGRAM
Unit type of package 2
CAR
Number of units in package 2
1
Package 2 height
4.1 CENTIMETER
Package 2 width
8.5 CENTIMETER
Package 2 length
4.5 CENTIMETER
Package 2 weight
0.095 KILOGRAM
Indivisible sale quantity
1
COMPLEMENTARY
Materials in contact with fluid
Ceramicfluorocarbon FPMstainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuitreverse polarity
Electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz
Measurement accuracy
+/- 0,5 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K
Repeat accuracy
+/- 0,25 % de la plage de mesure
Standards
IEC 61326-2-3NSF ANSI 61
Product certifications
CEcULusRCM
Vibration resistance
20 gn (f = 10-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
4.5 CENTIMETER
Package 1 length
8.5 CENTIMETER
Package 1 weight
0.096 KILOGRAM
Unit type of package 2
CAR
Number of units in package 2
1
Package 2 height
4.1 CENTIMETER
Package 2 width
8.5 CENTIMETER
Package 2 length
4.5 CENTIMETER
Package 2 weight
0.095 KILOGRAM
Indivisible sale quantity
1
ENVIRONMENT
Standards
IEC 61326-2-3NSF ANSI 61
Product certifications
CEcULusRCM
Vibration resistance
20 gn (f = 10-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PACKING UNITS
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
4.1 CENTIMETER
Package 1 width
4.5 CENTIMETER
Package 1 length
8.5 CENTIMETER
Package 1 weight
0.096 KILOGRAM
Unit type of package 2
CAR
Number of units in package 2
1
Package 2 height
4.1 CENTIMETER
Package 2 width
8.5 CENTIMETER
Package 2 length
4.5 CENTIMETER
Package 2 weight
0.095 KILOGRAM
Indivisible sale quantity
1