Pressure switch, XMLD, pressure range 500 bar, fixed scale, 2CO, 2 stages, TELEMECANIQUE

★★★★★
★★★★★

Pressure switch, XMLD, pressure range 500 bar, fixed scale, 2CO, 2 stages, TELEMECANIQUE

★★★★★
★★★★★

Comanda instant Pressure switch, XMLD, pressure range 500 bar, fixed scale, 2CO, 2 stages, TELEMECANIQUE

Pressure switch, XMLD, pressure range 500 bar, fixed scale, 2CO, 2 stages, TELEMECANIQUE
MAIN
Range of product
Telemecanique Pressure sensors XM
Product or component type
Electromechanical pressure sensor
Pressure sensor type
Electromechanical pressure sensor
Device short name
XMLD
Controlled fluid
Hydraulic oil (0-160 °C)
Fluid connection type
G 1/4 (female) conforming to ISO 228
Electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
AWG gauge
AWG 20...AWG 14
Cable entry
Cable gland 9-13 mm
Contacts type and composition
2 C/O snap action, silver contacts, 2 C/O staggered, silver contacts
Product specific application
Dual stage
Pressure switch type of operation
Detection of 2 single thresholds
Electrical circuit type
Control circuit
Scale type
Fixed differential
Local display
Without
Pressure actuator
Piston
Materials in contact with fluid
BrassFPM, FKMPTFEstainless steelsteel
Enclosure material
Zinc alloy
COMPLEMENTARY
Terminal block type
8 terminals
Operating rate
60 cyc/mn
Resistance across terminals
25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A
Setting
External
ENVIRONMENT
Standards
CECSA C22.2 No 14IEC 60947-5-1UL 508
Product certifications
CSAUL
Protective treatment
TC standard version
Operating position
Any position
Vibration resistance
4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz)
Shock resistance
50 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 1140, class I conforming to IEC 536, class I conforming to NF C 20-030
IP degree of protection
IP66 conforming to IEC 60529
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PACKING UNITS
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
6 CENTIMETER
Package 1 width
10.5 CENTIMETER
Package 1 length
14 CENTIMETER
Package 1 weight
0.75 KILOGRAM
Indivisible sale quantity
1
Fii primul care evalueaza acest produs
Pentru a evalua acest produs este necesar sa fii autentificat. > Click aici
Website detinut de Ringhiopol International S.R.L., CIF: RO33473129, Reg.Com: J8/1142/2014