Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking options description
Without locking of actuator
Local signalling
Without
COMPLEMENTARY
Positive opening
With NC contact
Actuator force for extraction
20 NEWTON
Operating rate
10 cyc/mn for maximum durability
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body material
Zamak
Head material
Zamak
ENVIRONMENT
Standards
CSA C22.2 No 14EN 1088/ISO 14119IEC 60204-1IEC 60947-5-1ISO 12100UL 508
Product certifications
CSAUL
Protective treatment
TC
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 61140
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
OFFER SUSTAINABILITY
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov